downloads [2019/11/08 11:16] – [Metrological (Calibration) Confirmation / Verification Procedures] rrandalldownloads [2019/11/15 21:46] – [Metrological (Calibration) Confirmation / Verification Procedures] rrandall
Line 2: Line 2:
  
 ===== Metrological (Calibration) Confirmation / Verification Procedures =====  ===== Metrological (Calibration) Confirmation / Verification Procedures ===== 
 +
 +{{ :metrology:to_33k1-4-141-1_30-aug-05_multimeters.pdf |T.O. 33k1-4-141-1, Calibration Procedure for Multimeters (30 August 2005) Size=765k}}
  
 {{ :metrology:t.o._33k6-4-15-1-calibration_procedure_for_micrometers_micrometer_heads_and_depth_micrometers-general.pdf|T.O. 33k6-4-15-1, Calibration Procedure for Micrometers, Micrometer Heads, and Depth Micrometers-General (30 April 2008) Size=2M}} {{ :metrology:t.o._33k6-4-15-1-calibration_procedure_for_micrometers_micrometer_heads_and_depth_micrometers-general.pdf|T.O. 33k6-4-15-1, Calibration Procedure for Micrometers, Micrometer Heads, and Depth Micrometers-General (30 April 2008) Size=2M}}
Line 14: Line 16:
  
 {{ :metrology:t.o._33k5-4-42-1-calibration_procedure_for_thermometers.pdf |T.O. 33k5-4-42-1, Calibration Procedure for Thermometers (30 January 2006) Size=60k}} {{ :metrology:t.o._33k5-4-42-1-calibration_procedure_for_thermometers.pdf |T.O. 33k5-4-42-1, Calibration Procedure for Thermometers (30 January 2006) Size=60k}}
 +
 +----
  
 Federal Specifications, section 4, "Quality Assurance Provisions", addresses methodologies for calibration: Federal Specifications, section 4, "Quality Assurance Provisions", addresses methodologies for calibration:
Line 22: Line 26:
  
 {{ :metrology:ggg-c-105c-caliper_micrometer_inside_outside_tube_and_gage_depth_micrometer.pdf |GGG-C-105C, Federal Specification: Caliper; Micrometer (Inside, Outside, Tube) and Gage, Depth Micrometer (July 10 1987) Size=2.1M}} {{ :metrology:ggg-c-105c-caliper_micrometer_inside_outside_tube_and_gage_depth_micrometer.pdf |GGG-C-105C, Federal Specification: Caliper; Micrometer (Inside, Outside, Tube) and Gage, Depth Micrometer (July 10 1987) Size=2.1M}}
 +
 +{{ :metrology:ggg-p-463c-surface_plate_granite_.pdf |GGG-P-463C, Federal Specification: Surface Plate (Granite) (September 10, 1973) Size=1.7M}}
 +
 +{{ :metrology:ggg-p-463c_amendment-1.pdf |GGG-P-463C, Federal Specification: Surface Plate (Granite) - Amendment 1 (June 15, 1977) Size=402k}}
  
 {{ :metrology:ggg-r-791h-measuring_rules.pdf |GGG-R-791H, Federal Specification: Measuring Rules (19 July 1994) Size=993k}} {{ :metrology:ggg-r-791h-measuring_rules.pdf |GGG-R-791H, Federal Specification: Measuring Rules (19 July 1994) Size=993k}}
 +
 +----
 +
 +The [[https://www.usbr.gov/tsc/techreferences/mands/rockmanual/rockmanual.html#9300|"Technical Service Center"]] for the "U.S. Department of the Interior Bureau of Reclamation" also has several publically available calibration procedures. One of their most popular calibration procedures is:
 +
 +[[https://www.usbr.gov/tsc/techreferences/mands/rockmanual/tan_earthmanualUSBR/USBR1007.pdf|USBR 1007-89, "Procedure for Calibrating Dial Indicators"]]
 +
 +----
 +
 +For calibrating most weighing scales, refer to [[https://www.nist.gov/pml/weights-and-measures/publications/nist-handbooks/other-nist-handbooks/other-nist-handbooks-0|NIST Handbook 44]], section 2.20, subsection N.1.1, "Test Procedures".
 +