This is an old revision of the document!



Warning: Undefined array key 1 in /webroot/r/i/richa010/primary/www/lib/plugins/imagebox/syntax.php on line 28

Warning: Undefined array key 1 in /webroot/r/i/richa010/primary/www/lib/plugins/imagebox/syntax.php on line 28

Warning: Undefined array key 1 in /webroot/r/i/richa010/primary/www/lib/plugins/imagebox/syntax.php on line 28

Downloads

Metrological (Calibration) Confirmation / Verification Procedures

T.O. 33k1-4-141-1, Calibration Procedure for Multimeters (30 August 2005) Size=765k

T.O. 33k6-4-15-1, Calibration Procedure for Micrometers, Micrometer Heads, and Depth Micrometers-General (30 April 2008) Size=2M

T.O. 33k6-4-552-1, Calibration Procedure for Calipers-General (30 July 2013) Size=206k

T.O. 33k6-4-1626-1, Calibration Procedure for Height Gages - Vernier, Dial and Digital-General (30 March 2009) Size= 30k

T.O. 33k6-4-2930-1, Calibration Procedure for Manually Operated Torque Wrenches 6% to 20% - General (30 September 2002 with Change 4, 30 May 2005) Size=99k

T.O. 33k6-4-427-1, Calibration Procedure for Pressure Gauge (30 May 2012) Size=101k

T.O. 33k5-4-42-1, Calibration Procedure for Thermometers (30 January 2006) Size=60k


Federal Specifications, section 4, “Quality Assurance Provisions”, addresses methodologies for calibration:

GGG-G-15C, Federal Specification: Gage Blocks and Accessories (Inch and Metric) (March 20 1975) Size=2.3M

GGG-G-17C, Federal Specification: General Purpose Gages (June 26 1987) Size=3.1M

GGG-C-105C, Federal Specification: Caliper; Micrometer (Inside, Outside, Tube) and Gage, Depth Micrometer (July 10 1987) Size=2.1M

GGG-P-463C, Federal Specification: Surface Plate (Granite) (September 10, 1973) Size=1.7M

GGG-P-463C, Federal Specification: Surface Plate (Granite) - Amendment 1 (June 15, 1977) Size=402k

GGG-R-791H, Federal Specification: Measuring Rules (19 July 1994) Size=993k


The "Technical Service Center" for the “U.S. Department of the Interior Bureau of Reclamation” also has several publically available calibration procedures. One of their most popular procedures is:

USBR 1007-89, "Procedure for Calibrating Dial Indicators"


For calibrating most weighing scales, refer to NIST Handbook 44, section 2.20, subsection N.1.1, “Test Procedures”.

"SWOT & Strategic Risk Assessment Bubble Chart" template in Excel (8-12-2018)

SWOT & Strategic Risk Assessment Bubble Chart (Excel)

SWOT & Strategic Risk Assessment Bubble Chart (Excel)
The “SWOT & Strategic Risk Assessment Bubble Chart” template (Excel)“ is based on the guidance provided from ISO 31000:2018, “Risk management — Principles and guidelines”. Use the SWOT to help identify up to 9 strategic risks. Then assign a point score (0-10) for the likelihood (probability) and “Consequences” (Impact) of each risk. These two scores (“Likelihood” and “Consequences”) will automatically be added to produce a “Risk Level” (between 1 and 10). And the “Bubble” chart will automatically update; reflecting the “Risk Level” both in location and size of the bubbles. The template also includes a “Risk Treatment Plan” (as per ISO 31000:2009, section 6.4). This template includes instructions for its use.

"Process Risk Assessment Bubble Chart" template in Excel (8-12-2018)

Process Strategic Risk Assessment Bubble Chart (Excel)

[Process Risk Assessment Bubble Chart (Excel)
The “Process Risk Assessment Bubble Chart” template (Excel)” is based on the guidance provided from ISO 31000:2018, “Risk management — Principles and guidelines”. Identify up to 9 risks in a process. Then assign a point score (0-5) for the likelihood (probability) and “Consequences” (Impact) of each risk. These two scores (“Likelihood” and “Consequences”) will automatically be added to produce a “Risk Level” (between 1 and 10). And the “Bubble” chart will automatically update; reflecting the “Risk Level” both in location and size of the bubbles. The template also includes a “Risk Treatment Plan” (as per ISO 31000:2018, section 6.4). This template includes instructions for its use.

"Calibration Recall" template Excel (5-5-2018)

Calibration Recall template screenshot

"Calibration Recall" template Excel (5-5-2018)
This simple Excel-based “Calibration Recall” template is designed for small companies (with under 150 instruments under calibration control) to comply with ISO 9001:2015 & AS9100D. It uses Color-coded “Conditional Cell Formatting” for visual management.

"DPMO-Sigma-Yield-Cpk Conversion Table Wallpaper" (1920x1080)

“DPMO-Sigma-Yield-Cpk Conversion Table Wallpaper” (1920×1080)

"DPMO-Sigma-Yield-Cpk Conversion Table Wallpaper" (1920x1080)
This is a “DPMO-Sigma-Yield-Cpk Conversion Table” with a black background, suitable for use as computer desktop wallpaper. The PNG image provides a quick reference to convert Yields to DPMOs to Sigma levels (Short Term & Long Term) as well as Cpk. This chart covers a range of 3.50 to 6.00 Sigma Short Term (ZST). And the row at 4.00 Sigma Short Term (ZST) is highlighted in light green to indicate a minimum acceptable process capability of 1.33 Cpk.